Summary
Abstract
The bactericidal effect of slightly acidic hypochlorous water (SAHW) on Salmonella Enteritidis, Escherichia coli, Staphylococcus aureus, Listeria monocytogenes, and Bacillus cereus, as well as some bacterial strains isolated from fresh lettuce was evaluated. Viable counts of all tested bacterial samples decreased immediately after treatment by SAHW. Most bacterial cells with the exception of B. cereus, and S. aureus were not culturable on TSA after treatment by 1 to 30 mg/L SAHW. Likewise, Pseudomonas sp., and Flavobacterium or Xanthomonas sp., Kurthia sp., Micrococcus sp., and Corynebacterium or Microbacterium sp. were not culturable on TSA after treatment by 30 mg/L SAHW. Viable counts of S. aureus, E. coli, Flavobacterium or Xanthomonas sp., and Pseudomonas sp. showed a 5 to 6 log cfu/mL reduction at day 0 and maintained a count of less than 1 log cfu/mL from day 1 to day 7 following treatment by 30 mg/L SAHW. Sodium hypochlorite (NaOCl, 0.5-1.0 mg/L) decreased the viable counts of S. Enteritidis to less than the lower limit of detection, 1 log cfu/mL, from day 1 to day 7 following treatment by 1 mg/L. NaOCl was not sufficient at 0.5-0.75 mg/L in reducing viable counts of S. Enteritidis because of a 2 to 5 log cfu/mL increase from day 2 to day 5 due to recovery from injury. Initial counts of S. Enteritidis after hydrogen
Study details
- Published in: Journal of Faculty Agriculture, Kyushu University, 55 (2), 275 280 (2010)
- Microbes studied: Salmonella Enteritidis, Escherichia coli, Staphylococcus aureus, Listeria monocytogenes, and Bacillus cereus
Source
Source: Journal of Faculty Agriculture, Kyushu University, 55 (2), 275 280 (2010)
Conditions tested
| Parameter | Value |
|---|---|
| Organisms | Bacillus spp., Escherichia coli, Listeria monocytogenes, Salmonella, Staphylococcus spp. |
| Relevant sectors | Food Processing, Produce & Packing |
| Publication | Journal of Faculty Agriculture, Kyushu University, 55 (2), 275, 2010 |
Reading this responsibly
Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.
Applying it
Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.