Summary
Abstract
The fungicidal effectiveness of electrolyzed oxidizing (EO) water on peach [Prunus persica (L.) Batsch.] fruit was studied. Fruit were inoculated with a spore suspension of 5 105 conidia/mL of Monilinia fructicola [(G. Wint.) Honey] applied as a drop on wounded and nonwounded fruits, or by a uniform spray-mist on nonwounded fruits. Fruit were immersed in tap water at 26 C for 5 or 10 minutes (control), or treated with EO water varying in oxidation-reduction potential (ORP), pH, and free available chlorine (FAC). Following treatment, fruit were held at 20 C and 95% relative humidity for 10 days to simulate retail conditions. Disease incidence was determined as the percentage of fruits showing symptoms of the disease, while severity was expressed as lesion diameter. EO water did not control brown rot in wound-inoculated fruits, but reduced disease incidence and severity in nonwound-inoculated peach. Symptoms of brown rot were further delayed in fruit inoculated by a uniform-spray mist compared with the nonwounded-drop-inoculated peaches. Fruit treated with EO water held for 8 days at 2 C, 50% RH, did not develop brown rot, until they were transferred to 20 C, 95% RH. The lowest disease incidence and severity occurred in fruit immersed in EO water for up to 5 minutes. EO water having pH 4.0, ORP 1,100 mV, FAC 290 mg L-1 delayed the onset of brown rot to 7 days, i.e., about the period peach stays in the market from a packing house to consumer. No chlorine-induced phytotoxicity was observed on the treated fruit. This study revealed that EO water is an effective surface sanitizer, but only delayed disease development.
Study details
- Published in: HortScience 36.7 (2001): 1310-1314
- Microbes studied: Fungi
Source
Source: HortScience 36.7 (2001): 1310-1314
Conditions tested
| Parameter | Value |
|---|---|
| Organisms | Fungi (general) |
| Relevant sectors | Agriculture & Livestock, Produce & Packing |
| Publication | HortScience, 2001 |
Reading this responsibly
Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.
Applying it
Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.