Study summary

In vitro fungicidal activity of acidic electrolyzed oxidizing water

Plant Disease · 2002

Summary

Abstract

Acidic electrolyzed oxidizing (EO) water, generated by electrolysis of a dilute salt solution, recently gained attention in the food industry as a nonthermal method for microbial inactivation. Our objective was to determine if EO water has potential to control foliar diseases in greenhouses. Test fungi suspended in distilled water were combined with EO water (1:9 water:EO water) for various time periods, the EO water was neutralized, and germination was assessed after 24 h. Germination of all 22 fungal species tested was significantly reduced or prevented by EO water. All relatively thin-walled species (e.g., Botrytis, Monilinia) were killed by incubation times of 30 s or less. Thicker-walled, pigmented fungi (e.g., Curvularia, Helminthosporium) required 2 min or longer for germination to be reduced significantly. Dilution of EO water with tap water at ratios of 1:4 and 1:9 (EO:tap water) decreased efficacy against Botrytis cinerea. The presence of Triton X-100 (all concentrations) and Tween 20 (1 and 10%) eliminated the activity of EO water against B. cinerea. EO water did not damage geranium leaf tissue and inhibited lesion development by B. cinerea when applied up to 24 h postinoculation. EO water has a wide fungicidal activity which could facilitate its use as a contact fungicide on aerial plant surfaces and for general sanitation in the greenhouse.

Study details

  • Published in: Plant Disease 86.3 (2002): 278-281
  • Microbes studied: Fungi

Source

Read the original study

Source: Plant Disease 86.3 (2002): 278-281

Conditions tested

ParameterValue
OrganismsFungi (general)
Relevant sectorsAgriculture & Livestock
PublicationPlant Disease, 2002

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.