Study summary

Reduction of Particulate Matter and Ammonia by Spraying Acidic Electrolyzed Water onto Litter of Aviary Hen Houses: A Lab-Scale Study

Transactions of the ASABE · 2017

Summary

Abstract

Particulate matter (PM) concentrations are high in cage-free aviary hen houses due to accumulation of litter on the floor and hen activities. The of a spraying agent such as acidic electrolyzed water (AEW) to mitigate PM levels and disinfect houses has been reported, and high spray dosages will reduce PM to a low level. However, spraying a high dose of AEW may generate high levels of ammonia (NH3) due to an increase in litter moisture content (LMC). Lab-scale experiments were conducted to assess the effect of AEW spray dosage and pH on PM and NH3 emissions from the litter of aviary hen houses. Four dynamic emission chambers (DECs) located in an environmentally controlled room were used for the evaluation. Three spray dosages of 25, 50, and 75 mL kg-1 dry litter d-1 (equivalent to area application rates of 125, 250, and 375 mL m-2, respectively) and three pH values of 3, 5, and 7 at a free-chlorine concentration of 200 mg L-1 were tested. Spraying occurred within 10 min once a day for five consecutive days. A no-spray regimen was used as the control. The results showed that higher spray dosages of AEW led to lower PM emissions. In particular, spraying dosages of 25, 50, and 75 mL kg-1 dry litter d-1 reduced PM levels by (mean SD) 71% 3%, 81% 1%, and 89% 1%, respectively, immediately after spraying. The PM reductions were still significant 24 h after spraying, averaging 57% 4%, 71% 5%, and 83% 1%, respectively. There was no significant difference (p = 0.30 to 0.43) in reduction efficiency among the PM sizes (i.e., PM1, PM2.5, PM4, PM10, and total suspended particulates). For NH3 emissions, spraying 75 mL kg-1 dry litter d-1 generated 5 to 6 times greater NH3 emissions when compared to 25 mL kg-1 dry litter d-1 due to the difference in LMC (22.6% vs. 13.0%). Meanwhile, spraying AEW of pH 7 yielded 2 to 3 times higher NH3 emissions than AEW of pH 3 at the same dosage. Ammonia emissions of all spray treatments were found to be higher than that of the control, albeit no significant difference between the control and the 25 mL kg-1 dry litter d-1 dosage at pH 3 or pH 5 (p = 0.81 and 0.47, respectively). Pearson correlation coefficients between NH3 and spray dosage (0.82) and pH value (0.46) indicated that spray dosage is more linearly correlated to NH3 emissions than pH value (p

Study details

  • Published in: Transactions of the ASABE 60.2 (2017): 497-506
  • Microbes studied: None

Source

Read the original study

Source: Transactions of the ASABE 60.2 (2017): 497-506

Conditions tested

ParameterValue
Relevant sectorsLivestock, Poultry & Eggs
PublicationTransactions of the ASABE, 2017

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.