Study summary

Sanitizing effectiveness of commercial active water technologies on Escherichia coli O157: H7, Salmonella enterica and Listeria monocytogenes

Food control · 2013

Summary

Abstract

Electrochemically activated water (ECAW), also known as electrolyzed water, and ozonized water are typically effective in inactivating bacteria, but their generation typically uses high current and voltage. A few simpler antimicrobial technologies that are also based on the application of a mild electrical current have been recently marketed to food retail and service customers claiming to have sanitizing properties for controlling bacteria. The objective of this study was to determine the sanitizing effect of some of these commercial technologies on Escherichia coli O157:H7, Listeria monocytogenes, and Salmonella enterica and compare them with sterile water, generated ECAW generated with a pilot size electrolyzing unit, and salt solutions sprayed using commercial device sprays. A concentration of 100 mg/L ECAW had sanitizing effects of at least 5 log CFU/mL reductions on liquid culture and more than 4 log CFU/coupon reductions for E. coli O157:H7, L. monocytogenes and Salmonella dried on stainless steel surface, respectively. No bacterial cells were detected by direct plate counting post-ECAW treatment. In contrast, the treatment of liquid cultures with any of the commercial technologies tested resulted in non-significant bacterial cell reductions greater than 0.5 log CFU/mL. Similarly, when cells had been dried on metal surfaces and treated with any of the water generated with those technologies, no reductions were observed. When the manufacturer s instructions were followed, the reduction of cells on surface was largely due to the physical removal by cloth-wiping after water fraction application. These results indicate that treatment with any of these portable technologies had no noticeable antimicrobial activity. These results would be helpful for guiding consumers when choosing a right sanitization to ensure food safety.

Study details

  • Published in: Food control 33.1 (2013): 232-238
  • Microbes studied: Escherichia coli O157:H7, Salmonella enterica, Listeria monocytogenes

Source

Read the full study (PDF)

Source: Food control 33.1 (2013): 232-238

Conditions tested

ParameterValue
OrganismsEscherichia coli, Listeria monocytogenes, Salmonella
Relevant sectorsContact surfaces, Food Processing
PublicationFood control, 2013

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.