Summary
Abstract
Hypochlorous acid (HOCl) solutions were evaluated for their virucidal ability against a low pathogenic avian influenza virus (AIV), H7N1. HOCl solutions containing 50, 100 and 200 ppm chlorine (pH 6) or their sprayed solutions (harvested in dishes placed at 1 or 30 cm distance between the spray nozzle and dish) were mixed with the virus with or without organic materials (5 fetal bovine serum: FBS). Under plain diluent conditions (without FBS), harvested solutions of HOCl after spraying could decrease the AIV titer by more than 1,000 times, to an undetectable level (
Study details
- Published in: Journal of Veterinary Medical Science 77.2 (2015): 211-215
- Microbes studied: Avian influenza
Source
Source: Journal of Veterinary Medical Science 77.2 (2015): 211-215
Conditions tested
| Parameter | Value |
|---|---|
| Organisms | Avian influenza, Influenza viruses |
| Relevant sectors | Livestock |
| Publication | Journal of Veterinary Medical Science, 2015 |
Reading this responsibly
Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.
Applying it
Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.