Study summary

Resistance of various shiga toxin-producing Escherichia coli to electrolyzed oxidizing water

Food Control · 2013

Summary

Abstract

The resistance of thirty two strains of Escherichia coli O157:H7 and six major serotypes of non-O157 shiga toxin-producing E. coli (STEC) plus E. coli O104:H4 was tested against electrolyzed oxidizing (EO) water using two different methods; modified AOAC 955.16 sequential inoculation method and minimum inhibitory concentration (MIC). In sequential inoculation method efficacy of sodium hypochlorite was also compared with equal free chlorine (45 mg/L) containing EO water. MIC experiments were conducted for 15 s testing period with free chlorine concentrations of 3.00, 2.50, 2.00, 1.50, 1.00, 0.50 and 0.25 mg/L. The individual strain resistance when tested using the sequential inoculation method was in between 5 and 10 positive tubes, where greater numbers of positive tubes indicate increased resistance of the respective strain to the particular sanitizer. The MIC of individual strains ranged from 0.50 to 1.50 mg/L free chlorine of EO water. In comparison to sodium hypochlorite at same free chlorine concentration EO water was more effective against all STEC cocktails tested. The resistance of STEC cocktails using sequential inoculation method was determined as E. coli O157 O103 O26 0111 O121 045 > O145. The similar pattern of resistance was observed when cocktails were subjected to MIC. The results indicate that different strains of same serotype can differ in their resistance toward an intervention. In addition, EO water treatment that reduces E. coli O157:H7 can equally if not more effectively reduce other non-O157 STEC tested.

Study details

  • Published in: Food Control 30.2 (2013): 580-584
  • Microbes studied: Escherichia coli O157:H7

Source

Read the original study

Source: Food Control 30.2 (2013): 580-584

Conditions tested

ParameterValue
OrganismsEscherichia coli
Relevant sectorsFood Processing
PublicationFood Control, 2013

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.