Study summary

Bactericidal effects of hypochlorous acid water against Vibrio parahaemolyticus contaminated on raw fish and shellfish

Korean Journal of Food Science and Technology · 2015

Summary

Abstract

The bactericidal effects of strongly acidic hypochlorous acid water (StAHA) and slightly acidic hypochlorous acid water (SlAHA) against Vibrio parahaemolyticus contaminated on surface of raw fish and shellfish were examined. V. parahaemolyticus contaminated with about 7.0 log CFU/g on the meat chunk of olive flounder (Paralichthys olivaceus), and yellow tail (Seriola quinqueradiata), and 4.0 log CFU/g on the shucked scallop (Patinopecten yessoensis) were not detected after washing with StAHA and SlAHA at a ratio of 30:1 on a sample weight basis. However, 1.0 log CFU/g of V. parahaemolyticus was survived on shucked oyster (Crassostrea gigas) under same treatment conditions. The bactericidal effects of acidic hypochlorous acid water against V. parahaemolyticus contaminated on surface of shucked oyster were not as effective as those against V. parahaemolyticus contaminated on surface of meat chunk of olive flounder, yellow tail, and shucked scallop. Such differences can be attributed to the complicated surface conformation of oyster.

Study details

  • Published in: Korean Journal of Food Science and Technology 47.6 (2015): 719-724
  • Microbes studied: Vibrio parahaemolyticus

Source

Read the full study (PDF)

Source: Korean Journal of Food Science and Technology 47.6 (2015): 719-724

Conditions tested

ParameterValue
OrganismsVibrio spp.
Relevant sectorsFood Processing, Seafood
PublicationKorean Journal of Food Science and Technology, 2015

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.