Study summary

Effectiveness of electrolyzed oxidizing water for inactivating Listeria monocytogenes in lettuce

Universitas Scientiarum · 2005

Summary

Abstract

The effectiveness of electrolyzed oxidizing (EO) water for the inactivation of L. monocytogenes insuspension and when inoculated on lettuce leaves was evaluated. An electrolytic cell for the production of EO water was built and a solution of 5% NaCl was used. The EO water produced had a residual chlorine concentration of 29 parts per million (ppm) and pH 2.83. Ten strains of L. monocytogenes isolated from processed chicken (109 CFU/ml) were inoculated into 9 ml of EO water or 9 ml of deionized water (control) and incubated at 15 C for 5, 10, 15 and 20 min. The surviving population of each strain was determined on Columbia agar. An exposure time of 5 min reduced the populations by approximately 6.6log CFU/ml. The most resistant strains to sodium hypochlorite (NaOCl) were selected and used in a strain mixture (9.56 log CFU/ml, 109UFC/ml approximately) for the inoculation of 35 lettuce samples, by the dip inoculation method using distilled water as control. The population mean of L. monocytogenes after treatment with EO water and distilled water was reduced by 3.92 and 2.46 log CFU/ml respectively (p=0.00001). EO water and 6% acetic acid (vinegar) were combined to improve the EO water effect on L. monocytogenes inoculated in lettuce; the effectiveness of this combination was examined. The results showed that there was a synergistic effect of both antimicrobial agents (population reduction by 5.49 logCFU/ml approximately) on the viability of L. monocytogenes cells.

Study details

  • Published in: Universitas Scientiarum 10.1 (2005): 97-108
  • Microbes studied: Listeria monocytogenes

Source

Read the full study (PDF)

Source: Universitas Scientiarum 10.1 (2005): 97-108

Conditions tested

ParameterValue
OrganismsListeria monocytogenes
Relevant sectorsFood Processing, Produce & Packing
PublicationUniversitas Scientiarum, 2005

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.