Abstract

The virucidal effects of two types of electrolyzed water, acidic electrolyzed water (AEW) and neutral electrolyzed water (NEW), on avian influenza viruses were studied. Virus titers of the highly pathogenic H5N1 virus and the low-pathogenic H9N2 virus irreversibly decreased by >5-log at 1 min after the viruses were mixed with NEW containing 43 ppm free available chlorine (FAC), but not with NEW containing 5 log at 1 min after the viruses were mixed with AEW, in which the concentration of the FAC ranged from 72 to 0 ppm. Thus, the virucidal effect of AEW did not depend on the presence of FAC. Reverse transcription polymerase chain reaction amplified fragments of the M and NP genes, but not the complete M gene, from RNA extracted from the AEW-inactivated virus. Moderate morphological changes were found under the electron microscope, although no changes were observed in the electrophoresed proteins of the AEW-inactivated virus. No viral genes were amplified from the RNA extracted from the NEW-inactivated virus, regardless of the length of the targeted genes. No viral particles were detected under the electron microscope and no viral proteins were detected by electrophoresis for the NEW-inactivated virus. Thus, this study demonstrated potent virucidal effects of AEW and NEW and differences in the virucidal mechanism of the two types of electrolyzed water.

Study details

  • Published in: Archives of Virology 159.3 (2014): 405-412
  • Microbes studied: avian influenza virus

Source

Read the original study

Source: Archives of Virology 159.3 (2014): 405-412

Conditions tested

ParameterValue
OrganismsInfluenza viruses, Viruses (general)
PublicationArchives of Virology, 2014

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.