Study summary

Transmission Electron Microscopic Analysis Showing Structural Changes to Bacterial Cells Treated with Electrolyzed Water and an Acidic Sanitizer

Journal of Food Science · 2012

Summary

Abstract

The effects of various sanitizers on the viability and cellular injury to structures of Escherichia coli and Listeria innocua were investigated. A food grade organic acidic formulation (pH 2.5) and acidic, neutral, and basic electrolyzed water [AEW (pH 2.7, oxidation reduction potential; ORP: 1100 mV, free available chlorine; FAC: 150 ppm), NEW (pH 6.9, ORP: 840 mV, FAC: 150 ppm), BEW (pH 11.6, ORP: 810 mV)] were used to treat E. coli and L. innocua cells. After 10 min of exposure to the sanitizers, changes to the bacterial numbers and cell structures were evaluated by plate counting and transmission electron microscopy (TEM), respectively. It was concluded from the results that the sanitizers reduced the E. coli cells between 2 and 3 log CFU/mL. Except for the BEW treatment, reductions in L. innocua population were greater (>1 log CFU/mL) than that of E. coli for all treatments. Data from the TEM showed that all sanitizers caused changes to the cell envelope and cytoplasm of both organisms. However, smaller changes were observed for L. innocua cells. Decrease in the integrity of the cell envelope and aggregation of the cytoplasmic components appeared to be mainly because of exposure to the sanitizers. The organic acid formulation and AEW were the most effective sanitizers against bacterial cells, indicating that penetration of acidic substances effectively caused the cell inactivation.

Study details

  • Published in: Journal of Food Science 77.4 (2012)
  • Microbes studied: Escherichia coli, Listeria innocua

Source

Read the full study (PDF)

Source: Journal of Food Science 77.4 (2012)

Conditions tested

ParameterValue
OrganismsEscherichia coli, Listeria monocytogenes
Relevant sectorsFood Processing
PublicationJournal of Food Science, 2012

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.