Study summary

Suitability of electrolyzed oxidizing water for the disinfection of hard surfaces and equipment in radiology

Environmental Health Science and Engineering · 2015

Summary

Abstract

Hospitals are faced with increasingly resistant strains of micro-organisms. When it comes to disinfection, individual parts of electronic equipment of angiology diagnostics such as patient couches of computer tomography (CT) and magnetic resonance imaging (MRI) scanners prove to be very hard to disinfect. Disinfectants of choice are therefore expected to possess properties such as rapid, residue-free action without any damaging effect on the sensitive electronic equipment. This paper discusses the of the neutral electrolyzed oxidizing water (EOW) as a biocide for the disinfection of diagnostic rooms and equipment.MethodsThe CT and MRI rooms were aerosolized with EOW using aerosolization device. The presence of micro-organisms before and after the aerosolization was recorded with the help of sedimentation and cyclone air sampling. Total body count (TBC) was evaluated in absolute and log values.ResultsThe number of micro-organisms in hospital rooms was low as expected. Nevertheless, a possible TBC reduction between 78.9992.50% or 50.5070.60% in log values was recorded.ConclusionsThe research has shown that the of EOW for the air and hard surface disinfection can considerably reduce the presence of micro-organisms and consequently the possibility of hospital infections. It has also demonstrated that the sedimentation procedure is insufficient for the TBC determination. The of Biocide aerosolization proved to be efficient and safe in all applied ways. Also, no eventual damage to exposed devices or staff was recorded.

Study details

  • Published in: Environmental Health Science and Engineering 13.1 (2015): 6
  • Microbes studied: Total Microbial Count

Source

Read the original study

Source: Environmental Health Science and Engineering 13.1 (2015): 6

Conditions tested

ParameterValue
OrganismsTotal microbial count
Relevant sectorsHealthcare
PublicationEnvironmental Health Science and Engineering, 2015

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.