Study summary

Roles of oxidation reduction potential in electrolyzed oxidizing and chemically modified water for the inactivation of food-related pathogens

Journal of Food Protection · 2000

Summary

Abstract

This study investigates the properties of electrolyzed oxidizing (EO) water for the inactivation of pathogen and to evaluate the chemically modified solutions possessing properties similar to EO water in killing Escherichia coli O157:H7. A five-strain cocktail (1010 CFU/ml) of E. coli O157:H7 was subjected to deionized water (control), EO water with 10 mg/liter residual chlorine (J.A.W-EO water), EO water with 56 mg/liter residual chlorine (ROX-EO water), and chemically modified solutions. Inactivation (8.88 log10 CFU/ml reduction) of E. coli O157:H7 occurred within 30 s after application of EO water and chemically modified solutions containing chlorine and 1% bromine. Iron was added to EO or chemically modified solutions to reduce oxidation reduction potential (ORP) readings and neutralizing buffer was added to neutralize chlorine. J.A.W-EO water with 100 mg/liter iron, acetic acid solution, and chemically modified solutions containing neutralizing buffer or 100 mg/liter iron were ineffective in reducing the bacteria population. ROX-EO water with 100 mg/liter iron was the only solution still effective in inactivation of E. coli O157:H7 and having high ORP readings regardless of residual chlorine. These results suggest that it is possible to simulate EO water by chemically modifying deionized water and ORP of the solution may be the primary factor affecting microbial inactivation.

Study details

  • Published in: Journal of Food Protection 63.1 (2000): 19-24
  • Microbes studied: Escherichia coli O157:H7

Source

Read the full study (PDF)

Source: Journal of Food Protection 63.1 (2000): 19-24

Conditions tested

ParameterValue
OrganismsEscherichia coli
Relevant sectorsFood Processing, In vitro
PublicationJournal of Food Protection, 2000

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.