Study summary

Reduction of Escherichia coli O157:H7 and Salmonella Typhimurium DT 104 on fresh produce using an automated washer with near neutral electrolyzed (NEO) water and ultrasound

Food Control · 2016

Summary

Abstract

Automated produce washers can be a useful processing aid when treating fresh produce contaminated with pathogens. The of near neutral pH electrolyzed (NEO) water as a wash or sanitizing solution has been shown to lead to significant reductions of Escherichia coli O157:H7 and Salmonella on fresh produce. To further enhance reported pathogen reductions, the effects of a combined NEO water (155 mg/L free chlorine, pH 6.5) and ultrasound wash protocol on lettuce and tomatoes inoculated with E. coli O157:H7 and S. Typhimurium DT 104 were studied. The effects of the pH of NEO water and washer agitation on pathogen reductions were also assessed. Inoculated tomatoes and lettuce leaves were treated with either chilled deionized water or NEO water, with or without 20 kHz ultrasound (130 W and 210 W). Tomatoes were treated for 1, 3 and 5 min while lettuce was treated for 5, 10 and 15 min. Ultrasound significantly increased the oxidation-reduction potential (ORP) of NEO water (p 0.05). Increased washing time and higher ultrasonic power led to significantly greater reductions of both pathogens on produce items (p

Study details

  • Published in: Food Control 63 (2016): 246-254
  • Microbes studied: Escherichia coli O157:H7, Salmonella Typhimurium

Source

Read the original study

Source: Food Control 63 (2016): 246-254

Conditions tested

ParameterValue
OrganismsEscherichia coli, Salmonella
Relevant sectorsFood Processing, Produce & Packing
PublicationFood Control, 2016

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.