Summary
Abstract
Fusarium Head Blight (FHB), caused by a blend of Fusarium species, is a destructive fungal disease of wheat and other small grain cereals. FHB has become an important issue in food and feed industry. Moreover, the majority of FHB pathogens have the ability to synthesize a range of mycotoxins. Although several physical and chemical control measures can be taken to control these fungi in the field, research is needed to provide new techniques for control during storage and transport of cereals. Mounting evidence shows that electrolyzed oxidizing water (EOW) has antimicrobial activity and might be a useful alternative for conventional control measures. The objective of the present work, was to investigate the influence of EOW on outgrowth and germination of Fusarium spp. and deoxynivalenol (DON) production. Both an in vitro and in vivo approach were pursued. In a first approach, a screening of the main FHB causing species was conducted. Secondly, the effect of EOW on Fusarium graminearum and the effect on DON biosynthesis was investigated using a trichothecene knockout mutant. These experiments showed an increase in DON levels upon sub lethal amendments of EOW to F. graminearum spores. In addition, the reactive oxygen species H2O2 was shown to govern this induction. Finally, the work was validated on a laboratory scale via an in vivo assay using wheat grains in which the Fusarium outgrowth was measured. The present work demonstrates that EOW has potential to control Fusarium spp. in wheat grains during transport and storage although sub lethal concentrations can result in increased DON biosynthesis.
Study details
- Published in: Food Control 23.2 (2012): 515-521
- Microbes studied: Fusarium graminearum
Source
Source: Food Control 23.2 (2012): 515-521
Conditions tested
| Parameter | Value |
|---|---|
| Relevant sectors | Agriculture & Livestock, Food Processing |
| Publication | Food Control, 2012 |
Reading this responsibly
Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.
Applying it
Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.