Study summary

In vitro antimicrobial activity of Medilox super-oxidized water

Annals of Clinical Microbiology and Antimicrobials · 2014

Summary

Abstract

Super-oxidized water is one of the broad spectrum disinfectants, which was introduced recently. There are many researches to find reliable chemicals which are effective, inexpensive, easy to obtain and use, and effective for disinfection of microorganisms leading hospital infections. Antimicrobial activity of super-oxidized water is promising. The aim of this study was to investigate the in-vitro antimicrobial activity of different concentrations of Medilox super-oxidized water that is approved by the Food and Drug Administration (FDA) as high level disinfectant. Material and methods In this study, super-oxidized water obtained from Medilox Soosan E & C, Korea device, which had been already installed in our hospital, was used. Antimicrobial activities of different concentrations of super-oxidized water (1/1, 1/2, 1/5, 1/10, 1/20, 1/50, 1/100) at different exposure times (1, 2, 5, 10, 30 min) against six ATCC strains, eight antibiotic resistant bacteria, yeasts and molds were evaluated using qualitative suspension test. Dey-Engley Neutralizing Broth Sigma-Aldrich, USA was used as neutralizing agent. Results Medilox was found to be effective against all standard strains (Acinetobacter baumannii 19606, Escherichia coli 25922, Enterococcus faecalis 29212, Klebsiella pneumoniae 254988, Pseudomonas aeruginosa 27853, Staphylococcus aureus 29213), all clinical isolates (Acinetobacter baumannii, Escherichia coli, vancomycin-resistant Enterococcus faecium, Klebsiella pneumoniae, Pseudomonas aeruginosa, methicillin-resistant Staphylococcus aureus, Bacillus subtilis, Myroides spp.), and all yeastsat 1/1 dilution in 1 minute. It was found to be effective on Aspergillus flavus at 1/1 dilution in 2 minutes and on certain molds in 5 minutes. Conclusion Medilox super-oxidized water is a broad spectrum, on-site producible disinfectant, which is effective on bacteria and fungi and can be used for the control of nosocomial infection.

Study details

  • Published in: Annals of Clinical Microbiology and Antimicrobials 13.1 (2014): 29
  • Microbes studied: Acinetobacter baumannii, Escherichia coli, Enterococcus faecalis, Klebsiella pneumoniae, Pseudomonas aeruginosa, Staphylococcus aureus, MRSE, VRE Bacillus subtilis, Myroides spp.

Source

Read the original study

Source: Annals of Clinical Microbiology and Antimicrobials 13.1 (2014): 29

Conditions tested

ParameterValue
OrganismsBacillus spp., Enterococcus spp., Escherichia coli, Pseudomonas spp., Staphylococcus spp.
Relevant sectorsHealthcare
PublicationAnnals of Clinical Microbiology and Antimicrobials, 2014

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.