Study summary

Evaluation of acidic electrolyzed water for phytotoxic symptoms on foliage and flowers of bedding plants

Crop Protection · 2003

Summary

Abstract

Acidic electrolyzed oxidizing (EO) water quickly kills a variety of fungi and shows promise as a broad-spectrum contact fungicide for control of foliar diseases of greenhouse-grown ornamentals. One requirement for use in the greenhouse is that EO water will not cause excessive phytotoxic symptoms on a wide variety of species. In one experiment, two applications of EO water did not damage 15 species of bedding plants. In a second experiment, EO water applied as a foliar spray three times per week for 4-7 weeks did not produce any visible phytoxicity on seven of the 12 species tested. Small, white spots were observed on flowers of geranium (Pelargonium x hortorum), impatiens (Impatiens walleriana), and vinca (Catharanthus roseus). Slight necrosis was observed on some leaf edges of petunia (Petunia x hybrida), and snapdragon (Antirrhinum majus). EO water generated from magnesium chloride produced more phytotoxicity than EO water generated by potassium chloride or sodium chloride. Phytotoxicity ratings of greater than 3 (0-10 scale) were not observed on any of the species tested. EO water caused slight damage to some plant species but, in general, appears to be safe to use as a foliar spray on a wide variety of bedding plants grown under greenhouse conditions.

Study details

  • Published in: Crop Protection 22.1 (2003): 73-77
  • Microbes studied: Total Microbial Count

Source

Read the full study (PDF)

Source: Crop Protection 22.1 (2003): 73-77

Conditions tested

ParameterValue
OrganismsTotal microbial count
Relevant sectorsAgriculture & Livestock
PublicationCrop Protection, 2003

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.