Evaluating use of neutral electrolyzed water for cleaning near-patient surfaces

Infection Control & Hospital Epidemiology · 2014

Summary

Abstract

This study aimed to monitor the microbiological effect of cleaning near-patient sites over a 48-hour period with a novel disinfectant, electrolyzed water. One ward dedicated to acute care of the elderly population in a district general hospital in Scotland. Lockers, left and right cotsides, and overbed tables in 30 bed spaces were screened for aerobic colony count (ACC), methicillin-susceptible Staphylococcus aureus (MSSA), and methicillin-resistant S. aureus (MRSA) before cleaning with electrolyzed water. Sites were rescreened at varying intervals from 1 to 48 hours after cleaning. Microbial growth was quantified as colony-forming units (CFUs) per square centimeter and presence or absence of MSSA and MRSA at each site. The study was repeated 3 times at monthly intervals. There was an early and significant reduction in average ACC (360 sampled sites) from a before-cleaning level of 4.3 to 1.65 CFU/cm2 at 1 hour after disinfectant cleaning (P

Study details

  • Published in: Infection Control & Hospital Epidemiology 35.12 (2014): 1505-1510
  • Microbes studied: Total Microbial Count, methicillin-susceptible Staphylococcus aureus (MSSA), methicillin-resistant Staphylococcus aureus (MRSA)

Source

Read the full study (PDF)

Source: Infection Control & Hospital Epidemiology 35.12 (2014): 1505-1510

Conditions tested

ParameterValue
OrganismsStaphylococcus spp., Total microbial count
Relevant sectorsContact surfaces, Healthcare
PublicationInfection Control & Hospital Epidemiology, 2014

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.