Study summary

Efficacy of sanitizers in reducing Escherichia coli O157: H7, Salmonella spp. and Listeria monocytogenes populations on fresh-cut carrots

Food Control · 2007

Summary

Abstract

Shredded carrots were inoculated with Escherichia coli O157:H7, Salmonella or Listeria monocytogenes and washed for 1 or 2 min with chlorine (Cl; 200 ppm), peroxyacetic acid (PA; 40 ppm) or acidified sodium chlorite (ASC; 100, 200, 500 ppm) under simulated commercial processing conditions. After washed, the carrots were spin dried, packaged and stored at 5 C for up to 10 days. Bacterial enumeration was significantly (P 0.05) reduced by 1, 1.5 and 2.5 log CFU/g after washing with ASC 100, 250 and 500 ppm, respectively. All sanitizers reduced pathogen load below that of tap water wash and unwashed controls. During storage at 5 C the bacterial load of all treatments increased gradually, but to different extent in different treatments. ASC inhibited bacterial growth more effectively than the other sanitizers and also maintained the lowest pathogen counts (

Study details

  • Published in: Food Control 18.11 (2007): 1383-1390
  • Microbes studied: Escherichia coli O157:H7, Salmonella spp., Listeria monocytogenes

Source

Read the original study

Source: Food Control 18.11 (2007): 1383-1390

Conditions tested

ParameterValue
OrganismsEscherichia coli, Listeria monocytogenes, Salmonella
Relevant sectorsFood Processing, Produce & Packing
PublicationFood Control, 2007

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.