Study summary

Efficacy of electrolyzed water in inactivating Salmonella enteritidis and Listeria monocytogenes on shell eggs

Journal of Food Protection · 2005

Summary

Abstract

The efficacy of acidic electrolyzed (EO) water produced at three levels of total available chlorine (16, 41, and 77 mg/liter) and chlorinated water with 45 and 200 mg/liter of residual chlorine was investigated for inactivating Salmonella Enteritidis and Listeria monocytogenes on shell eggs. An increasing reduction in Listeria population was observed with increasing chlorine concentration from 16 to 77 mg/liter and treatment time from 1 to 5 min, resulting in a maximal reduction of 3.70 log CFU per shell egg compared with a deionized water wash for 5 min. There was no significant difference in antibacterial activities against Salmonella and Listeria at the same treatment time between 45 mg/liter of chlorinated water and 14 A acidic EO water treatment (P 0.05). Chlorinated water (200 mg/liter) wash for 3 and 5 min was the most effective treatment; it reduced mean populations of Listeria and Salmonella on inoculated eggs by 4.89 and 3.83 log CFU/shell egg, respectively. However, reductions (log CFU/shell egg) of Listeria (4.39) and Salmonella (3.66) by 1 min alkaline EO water treatment followed by another 1 min of 14 A acidic EO water (41 mg/liter chlorine) treatment had a similar reduction to the 1 min 200 mg/liter chlorinated water treatment for Listeria (4.01) and Salmonella (3.81). This study demonstrated that a combination of alkaline and acidic EO water wash is equivalent to 200 mg/liter of chlorinated water wash for reducing populations of Salmonella Enteritidis and L. monocytogenes on shell eggs.

Study details

  • Published in: Journal of Food Protection 68.5 (2005): 986-990
  • Microbes studied: Salmonella Enteritidis, Listeria monocytogenes

Source

Read the full study (PDF)

Source: Journal of Food Protection 68.5 (2005): 986-990

Conditions tested

ParameterValue
OrganismsListeria monocytogenes, Salmonella
Relevant sectorsFood Processing, Livestock, Poultry & Eggs
PublicationJournal of Food Protection, 2005

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.