Study summary

Efficacy of Electrolyzed Oxidizing Water for Inactivating Escherichia coli O157:H7, Salmonella enteritidis, and Listeria monocytogenes

Applied and Environmental Microbiology · 1999

Summary

Abstract

The efficacy of electrolyzed oxidizing water for inactivating. Escherichia coli O157:H7, Salmonella enteritidis, and Listeria monocytogenes was evaluated. A five-strain mixture of E. coli O157:H7,S. enteritidis, or L. monocytogenes of approximately 108 CFU/ml was inoculated in 9 ml of electrolyzed oxidizing water (treatment) or 9 ml of sterile, deionized water (control) and incubated at 4 or 23 C for 0, 5, 10, and 15 min; at 35 C for 0, 2, 4, and 6 min; or at 45 C for 0, 1, 3, and 5 min. The surviving population of each pathogen at each sampling time was determined on tryptic soy agar. At 4 or 23 C, an exposure time of 5 min reduced the populations of all three pathogens in the treatment samples by approximately 7 log CFU/ml, with complete inactivation by 10 min of exposure. A reduction of 7 log CFU/ml in the levels of the three pathogens occurred in the treatment samples incubated for 1 min at 45 C or for 2 min at 35 C. The bacterial counts of all three pathogens in control samples remained the same throughout the incubation at all four temperatures. Results indicate that electrolyzed oxidizing water may be a useful disinfectant, but appropriate applications need to be validated.

Study details

  • Published in: Applied and Environmental Microbiology 65.9 (1999): 4276-4279
  • Microbes studied: Escherichia coli O157:H7, Salmonella enteritidis, Listeria monocytogenes

Source

Read the full study (PDF)

Source: Applied and Environmental Microbiology 65.9 (1999): 4276-4279

Conditions tested

ParameterValue
OrganismsEscherichia coli, Listeria monocytogenes, Salmonella
Relevant sectorsFood Processing
PublicationApplied and Environmental Microbiology, 1999

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.