Study summary

Effects of water hardness and pH on efficacy of chlorine-based sanitizers for inactivating Escherichia coli O157:H7 and Listeria monocytogenes

Food Control · 2013

Summary

Abstract

The effects of hardness and pH of water used to prepare electrolyzed oxidizing (EO) water and bleach solutions on the bactericidal activity of sanitizer prepared from the water were examined. EO water and bleach solutions were prepared with hard water of 0, 50, 100, and 200 mg/l as CaCO3 at pH 5, 6, 7, and 8. Increased water hardness tended to increase free chlorine and oxidation-reduction potential (ORP) and decrease pH of EO water. Chlorine levels also increased with water pH. Water hardness and pH only had minor effect on the pH of bleach solutions. Increasing hardness to 50 mg/l increased antimicrobial effect of EO water against Escherichia coli O157:H7, but reduced when water hardness further increased to 100 mg/l or higher. Water pH had no effect on EO water produced against E. coli O157:H7. Water hardness had no significant effect on bactericidal activity of EO water against Listeria monocytogenes but elevated water pH decreased bactericidal activity of EO water produced against L. monocytogenes. Bleach solution prepared using hard water at 200 mg/l or at pH 7 or higher had significant lower efficacy in inactivating E. coli O157:H7, but had no effect on the inactivation of L. monocytogenes. Results indicate that increasing the hardness or pH of water used to prepare EO water or bleach solutions will decrease the bactericidal activity of sanitizers prepared from the water.

Study details

  • Published in: Food Control 32.2 (2013): 626-631
  • Microbes studied: Escherichia coli O157:H7, Listeria monocytogenes

Source

Read the original study

Source: Food Control 32.2 (2013): 626-631

Conditions tested

ParameterValue
OrganismsEscherichia coli, Listeria monocytogenes
Relevant sectorsFood Processing, In vitro
PublicationFood Control, 2013

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.