Study summary

Effects of chlorine and pH on efficacy of electrolyzed water for inactivating Escherichia coli O157:H7 and Listeria monocytogenes

International Journal of Food Microbiology · 2004

Summary

Abstract

The effects of chlorine and pH on the bactericidal activity of electrolyzed (EO) water were examined against Escherichia coli O157:H7 and Listeria monocytogenes. The residual chlorine concentration of EO water ranged from 0.1 to 5.0 mg/l, and the pH effect was examined at pH 3.0, 5.0, and 7.0. The bactericidal activity of EO water increased with residual chlorine concentration for both pathogens, and complete inactivation was achieved at residual chlorine levels equal to or higher than 1.0 mg/l. The results showed that both pathogens are very sensitive to chlorine, and residual chlorine level of EO water should be maintained at 1.0 mg/l or higher for practical applications. For each residual chlorine level, bactericidal activity of EO water increased with decreasing pH for both pathogens. However, with sufficient residual chlorine (greater than 2 mg/l), EO water can be applied in a pH range between 2.6 (original pH of EO water) and 7.0 while still achieving complete inactivation of E. coli O157:H7 and L. monocytogenes.

Study details

  • Published in: International Journal of Food Microbiology 91.1 (2004): 13-18
  • Microbes studied: Escherichia coli O157:H7, Listeria monocytogenes

Source

Read the full study (PDF)

Source: International Journal of Food Microbiology 91.1 (2004): 13-18

Conditions tested

ParameterValue
OrganismsEscherichia coli, Listeria monocytogenes
Relevant sectorsFood Processing
PublicationInternational Journal of Food Microbiology, 2004

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.