Study summary

Effectiveness of electrolyzed water as a sanitizer for treating different surfaces

Journal of food protection · 2002

Summary

Abstract

The effectiveness of electrolyzed (EO) water at killing Enterobacter aerogenes and Staphylococcus aureus in pure culture was evaluated. One milliliter (approximately 109 CFU/ml) of each bacterium was subjected to 9 ml of EO water or control water (EO water containing 10% neutralizing buffer) at room temperature for 30 s. Inactivation (reduction of >9 log10 CFU/ml) of both pathogens occurred within 30 s after exposure to EO water containing approximately 25 or 50 mg of residual chlorine per liter. The effectiveness of EO water in reducing E. aerogenes and S. aureus on different surfaces (glass, stainless steel, glazed ceramic tile, unglazed ceramic tile, and vitreous china) was also evaluated. After immersion of the tested surfaces in EO water for 5 min without agitation, populations of E. aerogenes and S. aureus were reduced by 2.2 to 2.4 log10 CFU/cm2 and by 1.7 to 1.9 log10 CFU/cm2, respectively, whereas washing with control water resulted in a reduction of only 0.1 to 0.3 log10 CFU/cm2. The washing of tested surfaces in EO water with agitation (50 rpm) reduced populations of viable cells on the tested surfaces to

Study details

  • Published in: Journal of food protection 65.8 (2002): 1276-1280
  • Microbes studied: Enterobacter aerogenes, Staphylococcus aureus

Source

Read the full study (PDF)

Source: Journal of food protection 65.8 (2002): 1276-1280

Conditions tested

ParameterValue
OrganismsEnterobacter spp., Staphylococcus spp.
Relevant sectorsContact surfaces, Food Processing
PublicationJournal of food protection, 2002

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.