Summary
Abstract
OBJECTIVE: The purpose of the study was to determine whether electrolyzed oxidized water (EOW) functions as a bactericide in burn injury with Pseudomonas aeruginosa infection in a rat burn-wound model. METHODS:Anesthetized Sprague-Dawley rats (n = 31) were subjected to third-degree burns to 30% of total body surface area. Two days after injury, all rats were infected with P. aeruginosa using 1 mL of a suspension containing 1 x 10(8) colony-forming units. Rats were assigned to one of three groups: no irrigation (group I), irrigation with physiologic saline (group II), or irrigation with EOW (group III). Blood culture, endotoxin levels, and survival rates were determined. RESULTS: Survival rate was significantly higher in group III than in groups I or II (p
Study details
- Published in: Journal of Trauma and Acute Care Surgery 49.3 (2000): 511-514
- Microbes studied: Total Microbial Count
Source
Source: Journal of Trauma and Acute Care Surgery 49.3 (2000): 511-514
Conditions tested
| Parameter | Value |
|---|---|
| Organisms | Total microbial count |
| Relevant sectors | Healthcare, Public health, Wound Care & Dermatology |
| Publication | Journal of Trauma and Acute Care Surgery, 2000 |
Reading this responsibly
Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.
Applying it
Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.