Study summary

Combined effect of acidic electrolyzed water (AcEW) and alkaline electrolyzed water (AlEW) on the microbial reduction of fresh-cut cilantro

Food Control · 2015

Summary

Abstract

In the present study, the disinfection efficacy on fresh-cut cilantro of the combination of strongly acidic electrolyzed water (AcEW) and alkaline electrolyzed water (AlEW) was evaluated, in comparison with single slightly acidic electrolyzed water (SAEW) and single AcEW treatments. The populations of E. Coli O78 on inoculated cilantro treated by AlEW 5 min + AcEW 5 min, was not detected while 3.43 and 3.73 log10 CFU/g in the AlEW 2.5 min + AcEW 2.5 min and AcEW 2 min + AlEW 2 min + AcEW 2 min treatments respectively. Our results implied that the bactericidal abilities of the combination of AlEW and AcEW treatments were higher than that of single AcEW and SAEW, which also was demonstrated microscopically by scanning electron microscopy (SEM). Moreover, the efficacy of combination of AcEW and AlEW in reducing natural micro flora on fresh-cut cilantro was also evaluated compared with single AcEW and SAEW. The results showed that the combination of AlEW and AcEW had stronger sterilization ability than single AcEW and SAEW. Considering the utilizations of AlEW and disinfection efficacy, we suggest that the combination of AlEW and AcEW may also be a better choice in fresh-cut produce.

Study details

  • Published in: Food Control 50 (2015): 699-704
  • Microbes studied: Escherichia coli

Source

Read the original study

Source: Food Control 50 (2015): 699-704

Conditions tested

ParameterValue
OrganismsEscherichia coli
Relevant sectorsAgriculture & Livestock, Food Processing, Produce & Packing
PublicationFood Control, 2015

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.