Study summary

Bactericidal effect of electrolyzed neutral water on bacteria isolated from infected root canals

Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · 1999

Summary

Abstract

Objective. The purposes of this study were to examine the time-related changes in pH, oxidation-reduction potential, and concentration of chlorine of electrolyzed neutral water and to evaluate the bactericidal effect of electrolyzed neutral water against bacteria from infected root canals. Study Design. Various properties of electrolyzed neutral water pH value, oxidation-reduction potential, and concentration of chlorine were measured at different times after storage of the water in the open state, the closed state, or the closed-and-dark state. The bactericidal effect of the various electrolyzed neutral water samples was then tested against 17 strains of bacteria, including 15 strains isolated from infected canals, as well as against 1 strain of fungus. Each bacterial or fungal suspension was mixed with electrolyzed neutral water, and the 2 substances were reacted together for 1 minute. After incubation for 1 to 7 days, the bactericidal effect of the electrolyzed neutral water was determined. Results. The pH value and oxidation-reduction potential of electrolyzed neutral water remained almost unchanged when the water was stored in a dark, closed container. However, the concentration of chlorine decreased from 18.4 ppm to 10.6 ppm. Electrolyzed neutral water showed a bactericidal or growth-inhibitory effect against the bacteria. Conclusions. The results indicate that electrolyzed neutral water maintains a constant pH and oxidation-reduction potential when kept in a closed container without light and that it exhibits a bacteriostatic/bactericidal action against isolates obtained from infected root canals.

Study details

  • Published in: Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology 87.1 (1999): 83-87
  • Microbes studied: Total Microbial Count

Source

Read the original study

Source: Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology 87.1 (1999): 83-87

Conditions tested

ParameterValue
OrganismsTotal microbial count
Relevant sectorsDental
PublicationOral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology, 1999

Reading this responsibly

Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.

Applying it

Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.

Source

View the published study

Turn the evidence into a protocol

We size the system, set the concentration and contact time, write the SOP and assemble the citations — free, and in writing.