Summary
Abstract
The sanitization efficacy of slightly acidic electrolyzed water (SAEW) against food pathogens on selected fresh ready-to-eat (RTE) vegetables and sprouts was evaluated and compared to sodium hypochlorite (NaOCl) solution. RTE vegetables and sprouts were dip-inoculated with Escherichia coli (E. coli) and Salmonella spp. and dip-treated with SAEW, NaOCl solution for 5 min. SAEW treatment significantly (p
Study details
- Published in: Food Control 22.3 (2011): 601-607
- Microbes studied: Escherichia coli, Salmonella spp.
Source
Source: Food Control 22.3 (2011): 601-607
Conditions tested
| Parameter | Value |
|---|---|
| Organisms | Escherichia coli, Salmonella |
| Relevant sectors | Food Processing, Produce & Packing |
| Publication | Food Control, 2011 |
Reading this responsibly
Published figures are obtained under controlled conditions, usually on clean surfaces or in defined matrices. Organic load, surface condition, temperature and application coverage all affect real-world performance. Use these numbers to design a protocol, then validate it on your own site with environmental swabbing.
Applying it
Concentrations in this range are within the adjustable output of every EcoloxTech commercial system, so implementing this protocol is a settings question rather than a procurement one. Where the claim needs to sit on a registered label, see HOCl-AS200, EPA Reg. No. 101112-1.